Emergency Response for Businesses

Overview

The Montgomery Township Department of Fire Services offers fire prevention, training, and inspection services to our business community.

Offerings for businesses include:

Fire Inspections for Businesses

Please contact the Department of Fire Services at 267-649-7120 for any questions or to schedule an inspection.

Watch our "Business Fire Inspection" video on YouTube to learn more.

Video Highlights

All commercial businesses are required by Township Ordinance 69-3 to install a Knox Box that holds keys to their building to allow the Fire Department access after-hours and during emergencies. Only the Fire Department can open the Knox Box.
The Knox Box Program is coordinated in the following manner:
  • On new construction and/or major renovations, the Knox Box application will be obtained and submitted through the Montgomery Township Department of Planning and Zoning at 215-393-6920.
  • When the Knox Box is received by the applicant, please contact the Department of Fire Services at 267-649-7120 to obtain mounting location and instructions.
  • Any business who has changed locks to their building should contact the Fire Department to ensure that the proper keys are in the Knox Box. If the lock cylinder on an existing business Knox Box has not been changed since 2005, please contact the Department of Fire Services at 267-649-7120.

The Knox Box Program was instituted to help minimize property damage to business properties during an emergency while also helping business owners in maintaining a secure facility.

All commercial businesses are required to install a Truss Emblem on the front of their building per Township Ordinance 72-5.
The Truss Placard is used to identify buildings within the township that contain roof, floor, or a combination of roof and floor truss construction. The purpose is to allow firefighters to rapidly identify such buildings in order to initiate the appropriate actions to ensure firefighter safety during any emergency operations. Truss Placards are placed on the exterior of the building at highly visible, critical locations as determined by the Fire Marshal's Office.
 
The Truss Placard Program is coordinated in the following manner:
  • On new construction and/or major renovations, the Truss Placard application will be obtained and submitted through the Montgomery Township Department of Planning and Zoning at 215-393-6920.
  • When the Truss Placard is received by the applicant, please contact the Department of Fire Services at 267-649-7120. in regards to instructions and the mounting location.
The Department perpetuates the Truss Placard Program on existing buildings during the annual township wide Life Safety Inspection Program. If it is determined during the inspection process that Truss Placards are required for the building, the Truss Placards can be obtained by the business through the Montgomery Township Department of Planning and Zoning.

During fire inspections, the Fire Marshal's Office reviews the building's fire alarm system and related documentation.

Businesses should ensure that:

  • Fire alarm systems are inspected annually.
  • Required inspection records are maintained and available.
  • Sprinkler systems receive their required inspections.
  • Required inspection reports are provided to the fire department when requested.

Maintaining current inspection records helps demonstrate that the building's life-safety systems are being properly maintained.

Fire extinguishers must be properly located, accessible, and maintained.

Inspection Considerations

  • There should generally be no more than 75 feet between fire extinguishers.
  • Additional extinguishers may be required in areas such as lobbies or other specific locations.
  • Merchandise, carts, displays, or other objects must not block access to an extinguisher.
  • Employees should be able to quickly locate and access extinguishers during an emergency.

Fire Extinguisher Training

The fire department offers staff training for businesses that need additional instruction. Training may include hands-on instruction using actual fire extinguishers and live-fire demonstrations.

To request training, fill out our Fire Services Request form.

Fire inspections also include a review of the building's means of egress and exit lighting.

Businesses should ensure that designated exit routes remain accessible and that required exit signs and lighting are maintained and readily visible.

Extension Cords

Extension cords are generally prohibited in commercial settings when used as permanent wiring.

They may be used temporarily for purposes such as operating a fan or power tool, but they should not be used as a permanent substitute for electrical wiring.

Power Strips

A UL-listed power strip may be used subject to applicable restrictions.

When using a power strip:

  1. Verify that it is UL listed and has the appropriate marking or label.
  2. Do not daisy-chain power strips.
  3. Each power strip should be plugged directly into an appropriate wall receptacle.
  4. Do not plug one power strip into another power strip.

Daisy-chaining power strips can create an electrical overload and represents a potential fire hazard.

Storage must maintain adequate clearance from the ceiling, particularly in commercial buildings.

Required Clearance

  • Non-sprinklered buildings: Maintain 24 inches of clearance between the ceiling and storage.
  • Sprinklered buildings: Maintain 18 inches of clearance between the ceiling and storage.

If storage is too close to the ceiling, businesses may be instructed to move the items to a lower shelf or otherwise correct the condition.

Electrical rooms and electrical equipment require clear access and proper identification.

Clearance

Maintain approximately 36 inches of clear space around electrical equipment and keep the access path free of combustibles and obstructions.

Electrical Panel Inspection

During an inspection, officials may check that:

  • Electrical panels and boxes are properly identified.
  • Access to electrical equipment is unobstructed.
  • Open breaker spaces are properly covered.
  • Electrical equipment is clearly labeled.
  • Doors and panels are appropriately marked to identify what equipment is located behind them.
  • Generator and other electrical service equipment is properly secured and accessible.

Proper labeling is especially important during an emergency so firefighters can quickly identify electrical and mechanical equipment.

Businesses with sprinkler systems must maintain the systems and retain required inspection documentation.

Required records should demonstrate that the sprinkler system has been properly inspected and that identified deficiencies have been addressed.

Deficiencies

If an inspection identifies a deficiency:

  • The business is responsible for having the deficiency corrected.
  • Required repairs should be completed promptly.
  • Records documenting inspections and corrective work should be maintained.

Businesses that need to schedule a fire inspection should contact the Montgomery Township Department of Fire Services at 267-649-7120.

Fire Services Request Form

Please complete our Fire Services Request form to notify the Fire Department of your business's needs.

Contact Us

(name)

Fire Chief

Address:

Battalion 1

325 Stump Road, Montgomeryville, PA 18936

Battalion 2

441 Doylestown Road, Lansdale, PA 19446

Phone: 267-649-7120

Email Us

Staff Directory

Sign up to our News and Notices

Stay up to date on the Township's activities, events, programs and operations by subscribing to our News and Notices.